On grid HC6KSI PV inverter
The HC6KSI power inverter module is a photovoltaic grid connected inverter. It is suitable for household use as well as small photovoltaic power plants, which can be used in groups.
Features
Compact and Robust
● Aluminum alloy die casting enclosure, permanently anti-rust
● IP 65, ensuring waterproof and dustproof during the 25-year service life
● Integrated streamlined case design with elegant appearanceLight weight, only 11 kg for 5 kW inverter; dual-in-line wiring method, simplified one-person installation
● Industrial-grade high quality components, obtaining a 25-year design life
High conversion Efficiency, High Overload Capacity, Mort Power Generation Benefit
● High conversion efficiency up to 98.4%
● Internal double boards design, without wiring terminal connection, low failure rate, ensuring long-term continuous power generation of the inverter
● Self-adaptive to the weak grid conservative mechanism, ride-through in harsh environment
● 600 V withstand voltage, 90 ~ 550 V wide MPPT range, supporting input over 30%
Easy Operation, Intelligent Monitoring, Running Cost Reduction
● Remote wireless transmission and cloud storage of power generation and operational data
● One-click APP configuration, real-time query via smart phone, convenient and efficient
● Support meter communication interface, more accurate power generation data, ensuring the profits
● Remote software upgrade, parameter setting and troubleshooting query, greatly reducing the cost of operation and maintenance
● Provided with the functions of grid remote power control, dry contact control, sound and light alarm
The photovoltaic grid connected inverter system converts the direct current generated by the solar photovoltaic array into alternating current with the same frequency as the public grid voltage, so the system can meet the local load power consumption and the utility grid. In general, the public grid system can be seen as an AC voltage source with an infinite capacity. When the solar photovoltaic array in the solar photovoltaic power generation grid-connected system generates less electricity than the local load, the local load power is partially supplied by the public grid; when the photovoltaic array generates more electricity than the local load, the solar photovoltaic The system delivers excess power to the public grid for grid-connected power generation.
MODEL |
HC3KSI-D |
HC3.68KSI |
HC4KSI |
HC4.6KSI |
HC5KSI |
HC6KSI |
INPUT |
||||||
Max input power |
3900W |
4800W |
5200W |
6000W |
6500W |
7800W |
Max input voltage |
600V |
|||||
Start-up voltage |
120V |
|||||
MPPT voltage range |
90-550V |
|||||
Rated input voltage |
360V |
|||||
MPPT voltage range at full load |
150-480V |
200-480V |
200-480V |
230-480V |
250-480V |
300-480V |
Max input current |
11A×2 |
|||||
Max short circuit current |
12A×2 |
|||||
Number of MPPTS |
2 |
|||||
OUTPUT |
||||||
Max output power |
3000W |
3680W |
4000W |
4600W |
4900W(AUS) 5000 W(EUR) |
6000W |
Max output current |
13A |
16A |
17.4A |
20A |
21.3A(AUS) 21.8A(EUR) |
26.1A |
Rated grid-connected voltage |
Single phase 230 Vac
|
|||||
Grid-connected voltage range |
180-280Vac
|
|||||
Rated grid-connected frequency |
50/60H
|
|||||
Grid-connected frequency range |
45-55Hz/55-65HZ
|
|||||
THD |
<3%(rated output power
|
|||||
DC component |
<0.5%*rated output current
|
|||||
Power factor |
>0.99(rated output power)
|
|||||
Adjustable range of power factor |
0.8 leading-08 lagging
|
|||||
EFFICIENCY |
||||||
Max conversion efficiency |
97.8% |
|||||
European efficiency |
97.3% |
|||||
OTHERS |
||||||
Protection |
Islanding protection, Output short-circuit protection, Leakage current protection. DC reverse polarity protection.DC input impedance detection, DC switch
|
|||||
Operating temperature |
-25℃~+60℃(>45℃ downgrading) |
|||||
Relative humidity |
0%-100% |
|||||
Altitude |
4000m(>2000m downgrading) |
|||||
IP rating |
IP65 |
|||||
Cooling |
Natural cooling |
|||||
Display |
LED indicators |
|||||
Self-consumption at night |
<0.5W |
|||||
Communication |
RS485*2. Wi-fi/ Ethemet |
|||||
Noise |
<40 dB |
|||||
Installation method |
Wall-mounted |
|||||
DC wiring terminal |
MC |
|||||
AC wiring terminal |
Plug and Play |
|||||
Certification standards |
IEC/EN62109-1,IEC62109-2,AS/NZS 4777.2 2015,VDE 0126-1-1,VDE-AR-N-4105,VDE V 0124-100(GE),ENEL 2010 Ed. 2.1, CEI 0-21(ITA), G83, G59(UK). EN50438(NLD) |
|||||
Dimensions(W*D*H)(mm) |
370×126.5×420 |
|||||
Packaged dimensions(W*D *H)(mm) |
440×205×490 |
|||||
Net weight(kg) |
10.9 |
|||||
Gross weight(kg) |
12.5 |