Factory direct sales off grid solar inverter 8000W
● Independent MPPT control microprocessor system
● Independent inverter control microprocessor system featured with high-speed online stabilization
● Advanced SPWM technology, high-speed power MOS
● MPPT control using PWM technology enable to bear the maximum PV open-circuit voltage
● Operating mode selectable: PV priority or utility power priority
● Charging current selectable according to configured battery
● AC input with effective online synchronous stabilization technology
● Auto-tracking mains phase to ensure that inverter output voltage has same phase with utility voltage, reducing transfer time and peak surge
● No-load auto shutdown function (optional)
● Automatic frequency selection
● Auto Power-On/Off function; real-time monitoring, test and intelligent startup / shutdown by RS232 or USB interface communicating with PC; remote monitoring by optional SNMP networks
control, sound and light alarm
Pay attention to the wiring of the off-grid inverter:
(1) The panel switches are all in the “off” state, check if the load is short-circuited.
(2) Do not make the wiring order of the DC input connected to the terminal block, pay attention to the positive and negative polarity.
(3) It is absolutely forbidden to connect the DC input power supply to the inverter output terminal, and prohibit the output circuit from being short-circuited or grounded.
The connection between the battery and the inverter should be as short as possible, otherwise the harmonic leakage current from the cable will adversely affect the inverter and system equipment.
(4) The grounding terminal of the system must be grounded and the length of the grounding wire should be as short as possible. And do not make the system welding machine, motor and other high current equipment common grounding. Ensure that all grounding wires of the system are laid separately from the wires of high current electrical equipment.
Connect the battery and DC input terminals with 25mm2 wires, connect the mains and AC input terminals with 15mm2, connect the AC output and load terminals, and ensure that the ground terminal is connected to the ground.
MODEL |
HC3000 |
HC4000 |
HC3000 |
HC5000 |
HC6000 |
HC8000 |
Rated power |
3 kW |
4 kW |
3 kW |
5 kW |
6 kW |
8 kW |
Battery voltage |
96 Vdc |
192 Vdc |
||||
Operating mode |
PV priority / AC priority(Optional) |
|||||
PV INPUT |
||||||
Input voltage range |
96 ~ 200 Vdc |
192 ~ 400 Vdc |
||||
Max. charging current |
10 ~ 60 A (selectable) |
10 ~ 40 A(selectable) |
10 ~ 60 A (selectable) |
|||
Optimum operating voltage (Vmp) |
120 ~ 142 Vdc |
240 ~ 284 Vdc |
||||
Max. PV frequent (Pmax) |
5760 W |
7680 W |
11520 W |
|||
Max. conversion efficiency |
98% |
|||||
AC INPUT |
||||||
Input voltage |
165 ~ 275 Vac |
|||||
Input frequency |
40 ~ 70 Hz (overclocking: auto transfer to DC power supply) |
|||||
Output voltage |
220 Vac ± 5% |
|||||
Input power factor |
≥ 0.8 |
|||||
Max. efficiency |
88% (online mode) |
|||||
Max. charging current |
8 A |
12 A |
||||
Short circuit |
Current-limiting, transfer to bypass; air circuit-breaker |
|||||
INVERTER OUTPUT |
||||||
Output voltage |
220 Vac ± 5% |
|||||
Output frequency |
50 Hz / 60 Hz ± 1% (auto-sense) |
|||||
Waveform |
Sinusoidal |
|||||
Output power factor |
1 |
|||||
Waveform distortion |
≤ 5% (linear load) |
|||||
Transfer time (PV – AC) |
0 ms |
|||||
Max. efficiency |
92% |
|||||
Short circuit |
Current-limiting, transfer to bypass or system auto shutdown |
|||||
ALARMS |
||||||
Utility power abnormal |
4 s per beep , auto mute in 40 s |
|||||
Low battery |
0.2 s per beep |
|||||
Overload |
1 s per beep |
|||||
COMMUNICATIONS |
||||||
Communication interface |
RS232, USB, RS485, SNMP (optional) |
|||||
Dry contacts |
PV fault, low battery, overload, bypass, inverter fault, generator ON / OFF |
|||||
OTHERS |
||||||
Overload protections |
110% for 255 s; 125% for 60 s; 150% for 10 s |
|||||
Wiring |
Terminal blocks |
|||||
EMI |
EN62040-2:2006; EN61000-3-2:2006; EN61000-3-3:2008 |
|||||
IP rating |
IP20 |
|||||
Ambient temperature |
0℃ ~ 40℃ |
|||||
Relative humidity |
10% ~ 90% (non-condensing) |
|||||
Noise |
≤ 50 dB |
|||||
Operating altitude |
2000 m (derating 1% for each additional 100 m) |
|||||
Dimensions (W × D × H) (mm) |
560 × 265 × 725 |
|||||
Packaged dimensions (W × D × H) (mm) |
662×360 × 905 |
|||||
Net weight (kg) |
76 |
80 |
60 |
67 |
69 |
85 |
Gross weight (kg) |
85 |
89 |
69 |
76 |
78 |
94 |